ROOFING AND WATER PROOFING SYSTEMS

///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

PRIMING
Aplication ofAwazel Primer
ASTM D41.
APPLICATON
Awazel horizontal membrane with welded joints.
DETAIL
Torch applicationof membranes at upstand.
RAINWATER OUTLET
Drainage at the tiled survace
and waterproofing level.
2 layer torch applied system on timber deck.

1. Application of Primer
2. Application of parapet flashing.
3. Torch applied 2nd layer.
B) 1 layer system using Awazel membrane glue on Primer, light top surfacing of Awazel
bituminous aluminium paint.

1. Application of AMG on Primer surface.
2. Roofing membrane onto AMG.
3. Application of Awazel bituminous aluminium paint.
B) 1 layer system using Awazel membrane glue on Primer, light top surfacing of Awazel
bituminous aluminium paint.

1. Therma isulation mechanically fixed.
2. Primer.
3. Torch application of first layer.
4. Smoothing joint with hot round-nosed
trowel. 5. Torch application of mineral
surfaced membrane.
2 layer torch applied system on timber deck.

1. Application of Primer.
2. Mopping hot asphalt.
3. Rolling first layer membrane.
4. Sweeping out trapped air.
5. Completed 2nd layer.
6. Pour and roll 3rd layer membrane.
7. Asphalt boiler.
8. Separation sheet.
9. Sand bed.
10. Tiles.